Search results for " radiation dose"

showing 10 items of 10 documents

Efficacy of raw implementation and reduction dose protocols in CT colonoscopy: a single centre 4 years retrospective review

2015

Aims and objectives Methods and materials Results Conclusion Personal information References

Radiation safetyRadioprotection / Radiation dose CT Radiation safety Dosimetric comparisongenetic structuresRadioprotection / Radiation doseDosimetric comparisonCT
researchProduct

Cumulative radiation CT dose in young traumatic patients: a single centre 5 years retrospective review

2014

Radioprotection / Radiation dose CT Radiation safety Trauma
researchProduct

Stress-first single photon emission computed myocardial perfusion imaging

2016

Background. Myocardial perfusion imaging (MPI) with single photon emission tomography (SPET) is widely used in coronary artery disease evaluation. Recently major dosimetric concerns have arisen. The aim of this study was to evaluate if a pre-test scoring system could predict the results of stress SPET MPI, thus avoiding two radionuclide injections. Methods. All consecutive patients (n=309) undergoing SPET MPI during the first 6 months of 2014 constituted the study group. The scoring system is based on these characteristics: age >65 years (1 point), diabetes (2 points), typical chest pain (2 points), congestive heart failure (3 points), abnormal ECG (4 points), male gender (4 points), and…

Myocardial Perfusion Imaging Coronary Artery Disease Radiation Dose Stress-FirstRadiation DoseMyocardial Perfusion ImagingArticlesCoronary Artery DiseaseStress-First
researchProduct

CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks.

2014

An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the author…

Adultmedicine.medical_specialtyPopulationGuidelines as TopicRadiation DosageEffective dose (radiation)PediatricsRisk AssessmentCaliforniaRadiation ProtectionRisk FactorsNeoplasmsRadiation Ionizingmedicinemedia_common.cataloged_instanceHumansRadiology Nuclear Medicine and imagingMedical physicsEuropean UnionEuropean unioneducationChildMathematical ComputingNeuroradiologymedia_commoneducation.field_of_studyEvidence-Based Medicinemedicine.diagnostic_testbusiness.industryCT Radiation exposure DLP CTDI Radiation dose Absorbed doseInterventional radiologyGeneral MedicineEvidence-based medicineAbsorbed doseRadiologyRisk assessmentbusinessRadiologyTomography X-Ray ComputedLa Radiologia medica
researchProduct

CT coronary angiography at an ultra-low radiation dose (< 0.1 mSv): feasible and viable in times of constraint on healthcare costs

2013

Computed tomography coronary angiography (CTCA) has reached very high standards both in terms of diagnostic performance and radiation dose reduction. This commentary follows a report on CTCA using less than 0.1 mSv in selected patients. This is an extraordinary accomplishment, both for technology and for medicine. The difficult task is now to implement this tool in clinical practice so it can play the best possible role. CTCA can improve diagnostic pathways, can save money for healthcare systems and could even improve pharmacological therapy. All of this may happen, but it will require the combined effort of all the experienced operators in this field, including the referring clinicians. In…

Coronary angiographymedicine.medical_specialtylow radiation dosePharmacological therapyCT coronary angiographyCoronary Artery DiseaseCoronary AngiographyRadiation DosageSensitivity and Specificityhealthcare costsRadiation ProtectionHealth careCardiac CTHumansMedicineLow dose ctRadiology Nuclear Medicine and imagingMedical physicsConstraint (mathematics)Neuroradiologymedicine.diagnostic_testbusiness.industryscreeningRadiation doseReproducibility of ResultsInterventional radiologyHealth Care CostsGeneral MedicineUnited StatesFeasibility StudiesRadiologyTomography X-Ray ComputedbusinessEuropean Radiology
researchProduct

Patients perception of ionising radiation risks in CT ionising exposure. Does dose bill works?

2015

Communicating to patients the magnitude of risk related to ionizing radiation exposure is problematic because of the uncertainty in estimates derived principally from epidemiological studies of large populations [1-6]. Euratom directive 59/2013 requires that dose bill will be part of the radiological report in European Countries [7]. However, how a risk is framed has a profound effect on risk perception. To date, no previous studies evaluated which could be the best way to make patient friendly dose bill. Our aim was to evaluate patients' perception of radiation exposure related to routine CT and their understanding after dose bill.

Radioprotection / Radiation dose CT Radiation safety Outcomes
researchProduct

HOW MUCH DANGEROUS IS CT ACCORDING TO PATIENTS AND HOW DOES DOSE BILL AFFECT THEIR PERCEPTION OF IONIZING RADIATION?

2015

Aims and objectives Methods and materials Results Conclusion Personal information References

genetic structuresDosimetryEducation and trainingRadioprotection / Radiation doseRadioprotection / Radiation dose CT Education Dosimetry Education and trainingCTEducation
researchProduct

Abdominal Computed Tomography Angiography at 80kV: feasibility study.

2014

preliminary evaluation of different dose reduction algorithms in abdominal Computed Tomography Angiography (CTA) with standard scan protocols at 120kV vs. 80kV.prospective, randomized, crossover study. 60 consecutive patients who underwent CTA of the abdomen (Sensation 64, Siemens; Iomeprol 400 mgl/ml Bracco) for suspected or diagnosed Abdominal Aortic Aneurysm (AAA) were enrolled in the study. A standard 120kV/200mAs scan protocol was acquired in all patients (reference tube current modulated with Automatic Exposure Control). In each patient a second scan with 80kV/300mAs (Group 1; n. 20), 80kV/400mAs (Group 2; n. 20), 80kV/500mAs (Group 3; n. 20) was acquired. We used the same scan/recons…

Aged 80 and overMaleCross-Over StudiesAngiographyMiddle AgedRadiation Dosage120kV signal noiseComputed Tomography Abdominal CT Angiography radiation dose 80kVFeasibility StudiesHumansFemaleProspective StudiesSettore MED/36 - Diagnostica Per Immagini E RadioterapiaTomography X-Ray ComputedAlgorithmsAgedAortic Aneurysm AbdominalActa bio-medica : Atenei Parmensis
researchProduct

Low dose CT of the heart: a quantum leap into a new era of cardiovascular imaging.

2010

In 10 years, computed tomography coronary angiography (CTCA) has shifted from an investigational tool to clinical reality. Even though CT technologies are very advanced and widely available, a large body of evidence supporting the clinical role of CTCA is missing. The reason is that the speed of technological development has outpaced the ability of the scientific community to demonstrate the clinical utility of the technique. In addition, with each new CT generation, there is a further broadening of actual and potential applications. In this review we examine the state of the art on CTCA. In particular, we focus on issues concerning technological development, radiation dose, implementation,…

Coronary angiographymedicine.medical_specialtyCardiologyComputed tomographycardiac CTCoronary DiseaseCoronary AngiographyRadiation DosageCoronary artery diseaseComputed tomography coronary angiographyCoronary artery diseasemedicineTrainingLow dose ctHumansRadiology Nuclear Medicine and imagingMedical physicsNeuroradiologymedicine.diagnostic_testEquipment Safetybusiness.industryRadiation doseRadiation doseGeneral MedicineConventional coronary angiographymedicine.diseaseComputed tomography coronary angiography Conventional coronary angiography Coronary artery disease Radiation dose TrainingClinical realitySafety EquipmentbusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaRadiologyTomography X-Ray ComputedLa Radiologia medica
researchProduct

PATIENTS' KNOWLEDGE AND AWARENESS OF RADIATION DOSE AND RISKS FROM CT: DO PATIENTS NEED A PERSONALIZED COMMUNICATION OF DOSE BILL?

2015

Aims and objectives Methods and materials Results Conclusion Personal information References

genetic structuresEducation and training Education Dosimetry CT Radioprotection / Radiation doseDosimetryEducation and trainingRadioprotection / Radiation doseEducationCT
researchProduct